is it possible to install a combination switch (switch and receptacle) in place of a single pole switch 2 wire?
Only two wires coming into box . one white one black I want to operate a light and also have a functional outlet. Don't care if light has to be on for outlet to function. I have a Cooper TR274 combination single pole switch and grounding receptacle

Reply
JohnB.
Yes, you can replace the receptacle with a switch/receptacle. You can run a wire for the light out through holes in the top or bottom of the box. You can either connect the receptacle so it comes on only when the light comes on or connect it so it is powered all the time. If you buy the device it should come with enough information to connect it. One word of warning, make sure you turn the power off to the receptacle before opening up the box.

Ed
Probably not. It will depend on the wire size in the box It could be either 14 or 12 gauge. Since the switch is on a lighting circuit, it could well be 14. Your electrical code probably requires 12 gauge for plug circuits. Also apparently there is no ground wire. Again, your electrical code may require one on any new receptacle.




Related Images
                

Related News
Wed, 23 May 2012 16:20:38 GMT
Study: Switch to SBRT for prostate cancer could save $250M annually
Health Imaging
The use of stereotactic body radiation therapy (SBRT) rather than intensity-modulated radiation therapy (IMRT) for low- to intermediate-risk prostate cancer could produce a win-win combination and curb ballooning prostate cancer treatment costs while ...


Thu, 24 May 2012 07:21:12 GMT
EMI problems? Part four: It could be conduction
EDN.com
Conducted EMI noise is a consequence of the normal operation of switching circuits in combination with parasitic capacitances and inductances. Figure 1 illustrates the origin of EMI-noise sources that can couple into PCB traces.